    Building Electric Solution



    Royal Power solution support normal operations of various type of building and facility

    Generator is widly applied on various buildings as backup power, such as office buildings, skyscrapers,apartments,hotels,restaurants,shopping malls, post stations,schools,etc.

    Products demands and challenges

    1. Working conditions

    Under following conditions, generators are reliable to work, supply power and work 24hrs constantly with prime power supply (which include 10% overload for 1hr every 12hrs)
    1000m above the sea level Environment is from -15 C°to 40 C°, other environment generators are optional.

    2. Low working noise
    Super low noise can make buildings and facilities operate efficiently.

    3. Main and necessary protection devices
    Generator start mode should be auto. They must equip with AMF (automatic Mains Failure) functions and ATS, which realize auto start. When the mains is failure, the start time lags < 20s(adjustable), the generators can start automatically(there are three continuous auto start functions), mains/generator completely transferring time is < 20s. Thus, the generators can fully make sure the load time less than 30s. When the mains is on, the generators will maintain 0-300s running and then auto stop after cooling (adjustable).

    4. Stable performance and strong reliability
    The generators MTBF is over 1000hrs;
    Empty load volts of the generators are 95-105% of the rating voltage.

    Solution:

    The generators, with advance performance, adopts low noise design, equip PLC-5220 control panel which is with AMF functions. Through connection with ATS, it makes sure the alternative power supply instantly when the mains is off.
    Advantage:
    Complete set of products and solution ,reducing the users' demands for products technology, which will be easier for generator running and maintenance.
    The control system is with AMF function, which can auto start, with auto stop and alarm functions under various monitors.
    ATS is optional; it can be inside the generators for small power
    Super silent. The noise level of power below 30kva is below 60dBA
    Stable performance, MTBF is not less than 1000hrs.
    Compact dimension ,optionable devices can be added for enabling genset to run in frozen or high tempreture ambient condition
    Customized desin and develop upon customers’s request